Program 22 : Incoming Call Setup
22-03 : Trunk Ring Tone Range
Level:
IN
Description
Use Program 22-03 : Trunk Ring Tone Range to select the ring tone range for the trunk. The trunk
uses a ring tone in the range selected when it rings an extension. Eight ring tones are available.
Customize the Trunk Ring Tones in Program 82-01.
Input Data
Trunk Port Number 1 ~ 128
Item
No.
Item Input Data Description Default
Related
Program
01 Ring Tone Pat-
tern
0 = Tone 1
1 = Tone 2
2 = Tone 3
3 = Tone 4
4 = Melody 1
5 = Melody 2
6 = Melody 3
7 = Melody 4
8 = Melody 5
9 = Tone 5
10 = Tone 6
11 = Tone 7
12 = Tone 8
Use this program to select the ring
tone range for the trunk. The trunk
uses a ring tone in the range selec-
ted when it rings an extension.
Eight Ring Tones are available.
0 15-02
Table 4-8 Program 22-03 - Incoming Signal Frequency Patterns
Incoming Signal
Frequency Pattern
Type Frequency 1 Frequency 2 Modulation
Pattern 1 High
Middle
Low
1100Hz
660Hz
520Hz
1400Hz
760Hz
660Hz
16Hz
16Hz
16Hz
Pattern 2 High
Middle
Low
1100Hz
660Hz
520Hz
1400Hz
760Hz
660Hz
8Hz
8Hz
8Hz
Pattern 3 High
Middle
Low
2000Hz
1400Hz
1100Hz
760Hz
660Hz
540Hz
16Hz
16Hz
16Hz
Pattern 4 High
Middle
Low
2000Hz
1400Hz
1100Hz
760Hz
660Hz
540Hz
8Hz
8Hz
8Hz
Pattern 5 High
Middle
Low
1400Hz
760Hz
660Hz
540Hz
540Hz
540Hz
16Hz
16Hz
16Hz
Pattern 6 High
Middle
Low
1400Hz
760Hz
660Hz
540Hz
540Hz
540Hz
8Hz
8Hz
8Hz