Configure System Information
46
ProSAFE 10-Gigabit Smart Managed Switch XS728T and XS748T User Manual
5. Select System > Management > Time > Daylight Saving Configuration.
6. Select a Daylight Saving (DST) radio button:
Disable. Disable daylight saving time.
Recurring. Daylight saving time occurs at the same time every year. The start and
end times and dates for the time shift must be manually configured.
Recurring EU. The system clock uses the standard recurring daylight saving time
settings used in countries in the European Union. When this option is selected, the
rest of the applicable fields on the page are automatically populated and cannot be
edited.
Recurring USA. The system clock uses the standard recurring daylight saving time
settings used in the United States. When this option is selected, the rest of the
applicable fields on the page are automatically populated and cannot be edited.
Non Recurring. Daylight saving time settings are in effect only between the start date
and end date of the specified year. When this option is selected, the daylight saving
time settings do not repeat on an annual basis.
If you select any radio button other than the Disable radio button (which is the default
selection), the page adjusts to display additional fields.
7. Configure how the daylight saving settings recur as described in the following table.
Field Description
Begins At
Note: These fields do not apply if you select
the Recurring EU radio button or the
Recurring USA radio button.
If you select the Recurring radio button, specify the start
date and time of daylight saving time in the following fields:
Week. Configure the start week.
Day. Configure the start day.
Month. Configure the start month.
Hours. Configure the start hour.
Minutes. Configure the start minute.
If you select the Non Recurring radio button, specify the
start date and time of daylight saving in the following fields:
Year. Configure the start year.
Date. Configure the start date.
Month. Configure the start month.
Hours. Configure the start hour.
Minutes. Configure the start minute.

Table of Contents

Other manuals for NETGEAR ProSafe XS728T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSafe XS728T and is the answer not in the manual?

NETGEAR ProSafe XS728T Specifications

General IconGeneral
ModelXS728T
CategorySwitch
Switching Capacity560 Gbps
Forwarding Rate417 Mpps
Ports24 x 10G SFP+, 4 x 10G Base-T
ManagementWeb-based, SNMP
FeaturesACLs, QoS
Power SupplyInternal 100-240VAC, 50-60Hz
Operating Temperature0°C to 50°C (32°F to 122°F)
Operating Humidity90% maximum relative humidity, non-condensing
MAC Address Table Size32, 000 entries