3-CONTROLSANDINSTRUMENTS
Batterymasterswitch
NOTICE:Waitatleast60safteryouplacetheignition
keyintheOFFpositionbeforeturningmasterdisconnect
switchtoOFF .Thisallowsthemachinecontrollerstoshut
downproperly.
NOTE:Thebatterymasterswitchmustbeswitchedoffat
theendofeachworkingday,formachineserviceorfor
anyoperationsontheelectricalsystem.
Itactsasananti-theftdevicewhenthecabdoorsand
windowsarelocked.
Usethemasterdisconnectswitchtheenableordisable
electricalpowerfromthemachinebatteriestotheelectri-
calcomponents.Themasterdisconnectswitch(1)isin
thebatterycompartment.
Turnthemasterdisconnectswitchcounter-clockwiseto
disconnectbatterypower.
Turnthemasterdisconnectswitchclockwisetoconnect
batterypower.
NOTICE:Somemachineserviceproceduresrequirean
actualterminaldisconnectofthebatteries.Donotusethe
masterdisconnectswitchforthosetypesofprocedures,
suchasweldingonthemachine.