ENGLISH – 13
To start this procedure:
1. press and hold the
g
button for roughly 5 seconds:
the symbol on the display will ash slowly (“Figure 28“)
DISPLAY
STOP/SET
28
2. press and hold the
f
button: the symbol on the
display will ash slowly (“Figure 29“)
DISPLAY
OPEN
29
3. press the
g
button to start the acquisition proce-
dure; the on the display will start ashing more rapidly (“Fig-
ure 30“)
DISPLAY
STOP/SET
30
4. wait for the control unit to complete the device acquisition
phase; once it terminates, the display will remain steady lit
(“Figure 31“)
DISPLAY
31
5. press and hold the
f
button to move the door up
to the fully open position; the display will ash during the
manoeuvre (“Figure 32“). If necessary, use the
h
button to modify the door’s position
DISPLAY
OPEN
32
6. conrm the desired opening position by pressing the
g
button until the symbol shown in the gure ap-
pears, then release the button (“Figure 33“)
DISPLAY
STOP/SET
33
7. press and hold the
h
button to move the door up
to the fully closed position; the display will ash during the
manoeuvre (“Figure 34“). If necessary, use the
f
button to modify the door’s position
DISPLAY
CLOSE
34
8. conrm the desired closing position by pressing the
g
button for 5 seconds; the symbol on the display
will ash slowly (“Figure 35“)
DISPLAY
STOP/SET
35
9. press the
h
button to reach the exit symbol and
then press the
g
button once to exit the menu
(“Figure 36“)
DISPLAY
STOP/SET
36
10. press the
f
button to start the “Automatic force
search” procedure; wait for the door to open and close.
During this phase, the courtesy light will ash once a second
to signal that the procedure is being executed
11. at the end of the procedure, the display will be lit steady
(“Figure 37“).
DISPLAY
37
a
If, at the end of the procedure, the display ashes,
it means that an error has occurred. The procedure
must be restarted from point 1.