10 Error Messages
178 Total Station NPL-322 Instruction Manual
Job Manager
Cannot Assign 100.12
You have tried to set the current job as the control file.
Press any key to return to the previous screen. Then select a different job.
Can't Create 100.13
There is no space available to create a job or record a point.
Press any key to return to the Job Manager. Then use the
DEL softkey to delete old
jobs.
Existing Job 100.14
You have entered an existing job name for a new job.
Press any key and then change the name for the new job.
MAX 32Jobs 100.15
You are trying to create a new job when the maximum number of jobs (32) is already
stored.
Press any key to return to the Job Manager. Then use the
DEL softkey to delete old
jobs.
Programs
NO Stn Setup 100.16
You did not perform a station setup or BS check before entering the Programs
function.
B
Tip – Selecting Continue does not resume the last ST record. You should only use the
Continue option if you are sure that the previous ST coordinates and the current HA
orientation are correct. Otherwise, records in the Programs function may not be correct.
XY&Z coordinate are required
100.17
Three-dimensional coordinates are required in S-Plane function.
Press any key to return to the point input screen. Then enter a three-dimensional
point.
To ... Press ...
go to the Stn Setup menu
[2] or select Stn Setup
return to the BMS
[ESC]
go to the Programs menu [1] or select Continue