Total Station NPL-322 Instruction Manual 53
Getting Started 3
Rec mode field
The Rec mode setting controls how the [MSR1] and [MSR2] keys operate in the BMS.
The MSR only setting is the default measurement mode. After a measurement, the instrument stops in the BMS
and waits for you to press [ENT] before recording the point.
The Confirm setting displays the Record PT screen before data is recorded.
The ALL setting is a quick shooting and recording mode. The instrument automatically records the point using
the default PT/CD. The instrument then returns to the BMS for the next measurement.