FORM NO. 56043098 - Convertamatic
™
24, 26, 28, 32 / BA 625, 725, 825 - 15
SOLUTION SYSTEM
SOLUTION SYSTEM MAINTENANCE
• Solution Tank: See Figure 1. Weekly empty the solution tank; remove the solution Drain Hose (B) from its storage area (located on the right rear control handle
compartment). Direct the hose to a designated “Disposal Site” and fl ush the tank with clean water.
• Solution Filter: Remove and clean the inline Solution Filter (C). To access the fi lter housing for removal, work underneath the middle left side chassis panel. No
tools are needed to remove the fi lter (hand tighten only). Service Tip: The solution fi lter ball valve must be placed in the OFF (Closed) position. This prevents loss
of solution when servicing the fi lter strainer with a partial or full tank.
• Solution Delivery Trough: On the cylindrical scrub deck clean the holes in the delivery trough to assure even distribution of solution.
TROUBLESHOOTING GUIDE
Problem Possible Cause
Inadequate or no solution fl ow No solution in the tank
Solution tank fi lter ball valve in the off position
Clogged solution fi lter, valves and hoses
*Reference the Solution System Troubleshooting Guide fl owchart in this manual section for further component diagnostics.