ELECTRICAL SYSTEM
OUTPUT CONTROLS (CONTINUED):
Solution Switch (B):
This switch is used to toggle the state of the solution solenoid. Pressing and releasing this switch will alternately turn the solution solenoid on and off. The indicator
provides the following status information:
Off - Solution output is off.
Steady Green - Solution output is on. (solution pump is on and valve is open)
Flashing Yellow – Solution solenoid / contactor coil overload has occurred.
Extended Scrub Switch (G):
This switch is used to toggle the sate of the recycle pump and recycle valve (If available). Pressing and releasing this switch will alternately turn the recycle pump
and recycle valve on and off. The indicator provides the following status information:
Off – Recycle pump and valve off.
Steady Green – Recycle output is on and valve is open.
Detergent Switch (F):
This switch is sued to toggle the sate of the chemical pump (If available). Pressing and releasing this switch will alternately turn the chemical pump on and off. The
indicator provides the following status information:
Off – Chemical pump and valve off.
Steady Green – Chemical output is on.