Installation
3-9
Part 1089210A04
E 2010 Nordson Corporation
Idle Mode
Idle Mode is a low power state used to rapidly cycle the lamp from curing
power to an inactive, low light and heat state. See Table 3-4 for cycle
timing.
System must be in Lamp ON state to activate Idle Mode from the power
control, the Remote I/O, or through DeviceNett.
NOTE: The lamp should not remain in Idle Mode for longer than necessary.
After 10 minutes in Idle Mode the lamp will revert to Standby.
Table 3-4 Cycle Timing for Idle Mode
Cycle Timing
Idle to Lamp ON 3 seconds
Lamp ON to Idle 2 seconds
Remote Standby and Lamp On
The Off/Reset contact must be closed for the unit to go to Standby or On.
Once the lamphead is put into the Standby or On mode the lamphead will
remain in that mode until the Off/Reset contact is opened.
Standard Startup: Use to go from off, through the warm-up sequence, to
the SYSTEM ON mode.
1. On the host machine (or the master power supply selector), press the
SYSTEM ON button.
2. The unit goes through the warm up cycle for 15 seconds before turning
On.
3. After approximately 10 more seconds the unit has stabilized and is
ready to run. The system ready output contact closes.
Rapid Startup: Use if your system will sit idle in the STANDBY mode
before moving to SYSTEM ON mode.
1. On the host machine (or master power supply selector), press the
STANDBY button. There is an approximately 10 second warm-up time
for the magnetron filament.
2. After the 10 seconds the system goes into standby and remain there
indefintely.
NOTE: Do not leave the power supply in the standby mode for longer than
30 minutes. Prolonged standby periods will shorten the magnetron life.
3. Press the SYSTEM ON button to enable the UV light. The light turns on
instantly but takes approximately 8 seconds to stabilize. After 10
seconds, the system ready output contact closes.