Using the Menus
5-43
Part 1124631_01
E 2015 Nordson Corporation
Item Menu Function
Output
6
f
b
c
d
e
a
The pattern controller is equipped
with three standard outputs.
Select an output to indicate that the
line speed is above the start speed.
aTaptheOutput buttononthe
System Settings screen.
bSystemReady output signal
indicates that the system is
functioning normally and ready to
apply adhesive when enabled.
The System Ready output can
be programmed to be:
f: active high (24 VDC)
Or
e: active low (0 VDC) when the
system is ready.
c Alert output signal output
indicates that an Alert condition
is present. The Alert output can
be programmed to be:
f: active high (24 VDC)
Or
e: active low (0 VDC) when the
system is ready.
NOTE: Output can be
reconfigured as a minimum
speed output using the Prism
Utility available at
www.enordson.com/support.
d Fault/Machine Stop output is a
SPDT(Single Pole Double
Throw) dry contact output with
both normally open and normally
closed contacts. Use this setting
to set the power off condition
either to fault (e) or no fault (f).
Continued...