Using the Menus
5-44
Part 1124631_01
E 2015 Nordson Corporation
System Setup Screens (contd)
Item Menu Function
Input
7
c
a
b
1
2
d
e
f
The pattern controller is equipped
with six fixed inputs. The first five
inputs are for Remote Recipe
Selection (add-on software feature),
and one input is for Remote System
Idle.
aTaptheInput button on the
System Settings screen.
b Tapthecheckboxtoenablethe
Remote Re cipe Select ion.
Refer to the Recipe Codes Table
given next for setting up inputs
forRemoteRecipeSelection.
NOTE: The Prism utility can be
used to change the polarity of
these inputs. Refer to Using the
Prism Utility in Appendix B for
details.
c TaptosetRemoteSystemIdle
to:
1 Active low (0 VDC) setting
The system will be disabled
when no voltage is present on
the input.
2 Active high (24 VDC) setting
The system will be disabled
when 24 VDC is present on the
input.
d LED indicates incoming voltage
(hardware signal)
e LEDs showing input.
f Binary recipe number from LED
signals.