© 2017 Nortek AS
Status Description
Field
Description
Not used
Power level
00 = 0 (high)
01 = 1
10 = 2
11 = 3 (low)
Wakeup State
00 = bad power
01 = power applied
10 = break
11 = RTC alarm
Not used
Version 3 VelocityData Record Struct Definition (C99 standard)
typedef struct
{
unsigned short beamData1 : 4;
unsigned short beamData2 : 4;
unsigned short beamData3 : 4;
unsigned short beamData4 : 4;
} t_DataSetDescription4Bit;
typedef struct
{
unsigned long _empty1 : 1;
unsigned long bdScaling : 1;
unsigned long _empty2 : 1;
unsigned long _empty3 : 1;
unsigned long _empty4 : 1;
unsigned long echoFreqBin : 5;
unsigned long boostRunning : 1;
unsigned long telemetryData : 1;
unsigned long echoIndex : 4;
unsigned long activeConfiguration : 1;
unsigned long lastMeasLowVoltageSkip : 1;
unsigned long prevWakeUpState : 4;
unsigned long autoOrient : 3;
unsigned long orientation : 3;
unsigned long wakeupstate : 4;
} t_status;

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortek Signature Series and is the answer not in the manual?

Nortek Signature Series Specifications

General IconGeneral
TypeAcoustic Doppler Current Profiler (ADCP)
Operating Temperature-5°C to +45°C
Storage Temperature-20°C to +60°C
Temperature SensorIntegrated
Pressure SensorIntegrated
Compass and Tilt SensorIntegrated
Data StorageInternal memory
Communication InterfacesEthernet, RS-232
Depth RatingUp to 6000 meters (depending on model)
Data OutputASCII, binary
Beam AngleVaries by model
Velocity Accuracy±0.5% of measured velocity ±1 mm/s