5.1 List of Commands
Command
Description
Scope
START
Go in measurement mode
Command mode
MC
Go in command mode
Confirm mode
RM
Go in data retrieval mode
Confirm mode
CO
Continue in measurement mode.
Confirm mode, Data
retrieval mode
INQ
Inquiry instrument state
All modes
SETINST /
GETINST /
GETINSTLIM
Set/Get Main Instrument Settings
Get Instrument Setting Limits
Command mode
SETCLOCK/
GETCLOCK
Set/Get Real Time Clock
Command mode, Data
retrieval mode
SETCLOCKSTR/
GETCLOCKSTR
Set/Get Real Time Clock using a string argument
Command mode, Data
retrieval mode
SETPLAN/
GETPLAN/
GETPLANLIM
Set/Get Plan Settings
Get Plan Limits
Command mode
SETAVG/
GETAVG/
GETAVGLIM
Set/Get Averaging Mode Settings
Get Averaging Mode Limits
Command mode
SETBURST/
GETBURST/
GETBURSTLIM
Set/Get Burst Profile Settings
Get Burst Limits
Command mode
SETBURSTHR/
GETBURSTHR/
GETBURSTHRLIM
Set/Get Burst HR Profile Settings
Get Burst HR Limits
Command mode
SETECHO/
GETECHO/
GETECHOLIM
Set/Get Echo Sounder settings
Command mode
SETBT/
GETBT/
GETBTLIM
Set/Get Bottom Track Settings
Get Bottom Track Limits
Command mode
SETALTERNATE/
GETALTERNATE/
GETALTERNATELI
M
Set alternating, dual configuration times.
Command mode
GETMEM
Returns the amount of data the various modes will
store to the recorder in Mbytes/hour
Command mode
SETTRIG/
GETTRIG/
GETTRIGLIM
Sets / gets the parameters and limits for Trigger.
Command mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortek Signature Series and is the answer not in the manual?

Nortek Signature Series Specifications

General IconGeneral
TypeAcoustic Doppler Current Profiler (ADCP)
Operating Temperature-5°C to +45°C
Storage Temperature-20°C to +60°C
Temperature SensorIntegrated
Pressure SensorIntegrated
Compass and Tilt SensorIntegrated
Data StorageInternal memory
Communication InterfacesEthernet, RS-232
Depth RatingUp to 6000 meters (depending on model)
Data OutputASCII, binary
Beam AngleVaries by model
Velocity Accuracy±0.5% of measured velocity ±1 mm/s