Introduction 5
© 2017 Nortek AS
1 Introduction
The primary objective of this manual is to provide the information needed to control a Nortek
product that is based on the AD2CP hardware platform. This includes all instruments in the
Signature series. It is aimed at system integrators and engineers with interfacing experience, but
it also includes examples on how to configure and start the instrument for more unexperienced
integrators. The document's scope is limited to interfacing and does not address general
performance issues of the instrument. For a more thorough understanding of the principles, we
recommend the Principles of Operation and for information about how to operate the
instrument, we recommend the Operation Manual.
The document is complete in the sense that it describes all available commands and modes of
communication. For most users, it will make sense to let the supplied Nortek software do most of
the hardware configuration and then let the controller limit its task to starting/stopping data
collection.
As always, these types of documents are subject to change. We recommend that you check
http://www.nortek-as.com/en/support or contact Nortek to ensure you have the all the latest
information and versions of any software you plan to use.
If you have any comments or suggestions on the information given here, please let us know. Your
comments are always appreciated; our general e-mail address is inquiry@nortek.no.
Revision
Version 1 - Initial Document
Version 2
20.10.2015
Version 3
01.03.2016
Version 4
14.03.2016
Version 5 - New commands
30.09.2016
Version 6 - Release 1, 2017
10.02.2017
Version 7 - Release 2, 2017
20.10.2017

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortek Signature Series and is the answer not in the manual?

Nortek Signature Series Specifications

General IconGeneral
TypeAcoustic Doppler Current Profiler (ADCP)
Operating Temperature-5°C to +45°C
Storage Temperature-20°C to +60°C
Temperature SensorIntegrated
Pressure SensorIntegrated
Compass and Tilt SensorIntegrated
Data StorageInternal memory
Communication InterfacesEthernet, RS-232
Depth RatingUp to 6000 meters (depending on model)
Data OutputASCII, binary
Beam AngleVaries by model
Velocity Accuracy±0.5% of measured velocity ±1 mm/s

Related product manuals