4.3.8 Job-Offset-Assy and Basket-Assy
(1) Open the Cover Assy-Top.
(2) Unscrew screw 1, remove Frame-Duct 2, then remove the connector (remove the
connector through the shaft)
(3) Remove the 2 hinges, then remove the Job-Offset-Assy 3, and disconnect the connector.
(4) Unscrew 2 screws 4, then remove the 2 hinges, and remove the Cover Assy-Top (Sub)
5.
(5) Remove the six screws 6 of the Guide-Link-R and the three screws 7 of the Guide-Link-
L. Remove the Plate-Top and the Basket Assy 8 with their interlock.
(6) Remove the 2 hinges, then remove the Cover Assy-Top (Sub) 9
(7) Remove the Side Cover (L) Rear 0.
(8) Remove the E-ring A, unscrew 2 screws B, then remove the Plate-Support (Top) C,
Collar D, Shaft-Top (A) E, Spring-Torsion-Top (L) F, Spring-Torsion-Top (B) G.
(9) Unscrew 3 screws H, then remove the Gear-Assy-L I.
(10) Unscrew 3 screws J, then remove Gear-Assy-R K.
(11) Remove the high toner Assy tube L, then remove Basket-Assy M.