4 – 4
ItemNo. Specification Drawing Adjustment method
Gap between the con-
tact and the monitor
0.3mm or more
Touching
Adjust lever
Contact
Motor PCB
Verify the following.
Make sure that the
gap between the con-
tact and the motor
PCB is 0.3 mm or
more.
At the time of printing
test, make sure that
the contact touches
the motor PCB and it
enters reduced speed
mode when the adjust
lever is set to range 2
and 4.
0.3mm or
more