80-JB400-1 Rev. D 3-13
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
General Wiring and Installation Guidelines Routing and Protecting Cables
Access Holes
• Use existing holes for cable routing.
• If you drill, drill the smallest hole for the purpose:
- 1-1/2" hole is recommended for cables with a 9-pin DSUB connector, e.g., SDM cable.
- 1" hole is needed for the connectors on the antenna cable.
• Finish holes prior to routing cables:
- Debur holes.
- Use supplied grommet/convoluted tubing with internal holes.
- Extend convoluted tubing beyond the hole.
Stress Relief
• At the MAS, tie-wrap cables to each other to reduce stress on any individual cable.
• Ensure cables have enough slack so connections are not being pulled.
Fire Wall
of Vehicle
Tie-wraps
Access hole
sealed with
grommet
Convoluted
Tubing
06AAA_89