EasyManua.ls Logo

Omron 3G3MX2 - Page 296

Omron 3G3MX2
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-179
5-14 Other Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
Major Differences between High-frequency Mode and Normal Mode
Note: In the high-frequency mode, the values are fixed and thus parameters b049, A097, A098 and b089
are not displayed.
Function name
High-frequency
mode
Normal mode
Heavy Load/Light Load
Selection (b049)
Heavy load rating (CT) Heavy load rating (CT) Light load rating (VT)
Maximum Frequency
(A004)
1000 [Hz]
400 [Hz]
400 [Hz]
Starting Frequency
(b082)
0.10 to 100.0 [Hz]
0.10 to 9.99 [Hz]
0.10 to 9.99 [Hz]
Carrier Frequency
(b083)
2.0 to 10.0 [kHz]
2.0 to 15.0 [kHz]
2.0 to 10.0[kHz]
Control Method (A044)
00: Constant torque
characteristics
01: Reduced torque
characteristics
02: Free V/f setting
00: Constant torque
characteristics
01: Reduced torque
characteristics
02: Free V/f setting
03: Sensorless vector
control
00: Constant torque
characteristics
01: Reduced torque
characteristics
02: Free V/f setting
Acceleration Pattern
Selection (A097)
Deceleration Pattern
Selection (A098)
00: Line
00: Linear
01: S shape curve
02: U shape curve
03: Reverse-U shape
curve
04: EL-S shape curve
00: Linear
01: S shape curve
02: U shape curve
03: Inverted U shape
curve
04: EL-S shape curve
Automatic Carrier
Reduction (b089)
00: Disabled
00: Disabled
01: Enabled, depends on
current
02: Enabled, depends on
fin temperature
00: Disabled
01: Enabled, depends
on current
02: Enabled, depends
on fin temperature

Table of Contents

Other manuals for Omron 3G3MX2

Related product manuals