6-8 List of Modbus Communication (Modbus-RTU) Data
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
6
Communication Function
144Bh
Communication Speed
Selection
C071 R/W
03 (2,400 bps)
04 (4,800 bps)
05 (9,600 bps)
06 (19.2 kbps)
07 (38.4 kbps)
08 (57.6 kbps)
09 (76.8 kbps)
10 (115.2 kbps)
−
−
144Ch
Communication Station
No. Selection
C072 R/W 1 to 247 −
144Dh
Reserved −−− − −
144Eh
Communication Parity
Selection
C074 R/W
00: Disabled
01: Even
02: Odd
−
−
144Fh
Communication Stop Bit
Selection
C075 R/W
1: 1 bit
2: 2 bits
−
1450h
Operation Selection on
Communication Error
C076 R/W
00: Trip
01: Trip after deceleration
stop
02: Ignore
03: Free-run stop
04: Deceleration stop
−
1451h
Communication Error
Timeout Time
C077 R/W
0: Timeout disabled
0.01 [s]
1 to 9999
1452h
Communication Wait
Time
C078 R/W 0 to 1000 1 [ms]
1453h
to
1454h
Reserved −−− − −
1455h FV Adjustment C081 R/W 0 to 2000 0.1 [%]
5-40
1456h FI Adjustment C082 R/W 0 to 2000 0.1 [%]
1457h
to
1458h
Reserved −−− − −
1459h Thermistor Adjustment C085 R/W 0 to 2000 0.1 [%] 5-120
145Ah
to
145Eh
Reserved −−− − −
145Fh Debug Mode Selection C091 R
For factory adjustment (Do
not change.)
−−
1460h
to
1463h
Reserved −−− − −
1464h
Communication
Selection
C096 R/W
00: Modbus communication
(Modbus-RTU)
01: Co-inverter
communication
02: Co-inverter
communication
(management)
− 6-22
1465h Reserved −−− − −
Register
No.
Function name
Parameter
No.
R/W
Monitor and setting
parameters
Data
resolution