7 - 5
7 Precautions for Use of Parameters for Drive Programming
Drive Programming User’s Manual (I580-E2)
7-3 Parameters Affected by PID Enabled/Disabled
7
7-3 Parameters Affected by PID
Enabled/Disabled
The set values are scaled by the settings for A071/A075.
Parameter
No.
Description
Data
A071 01 or 02 A071 00
A011 FV Start Frequency Converted value set value (A075) Set value
A012 FV End Frequency Converted value set value (A075) Set value
A020 1st Multi-step Speed Reference 0 Converted value set value (A075) Set value
A021 Multi-step Speed Reference 1 Converted value set value (A075) Set value
A022 Multi-step Speed Reference 2 Converted value set value (A075) Set value
A023 Multi-step Speed Reference 3 Converted value set value (A075) Set value
A024 Multi-step Speed Reference 4 Converted value set value (A075) Set value
A025 Multi-step Speed Reference 5 Converted value set value (A075) Set value
A026 Multi-step Speed Reference 6 Converted value set value (A075) Set value
A027 Multi-step Speed Reference 7 Converted value set value (A075) Set value
A028 Multi-step Speed Reference 8 Converted value set value (A075) Set value
A029 Multi-step Speed Reference 9 Converted value set value (A075) Set value
A030 Multi-step Speed Reference 10 Converted value set value (A075) Set value
A031 Multi-step Speed Reference 11 Converted value set value (A075) Set value
A032 Multi-step Speed Reference 12 Converted value set value (A075) Set value
A033 Multi-step Speed Reference 13 Converted value set value (A075) Set value
A034 Multi-step Speed Reference 14 Converted value set value (A075) Set value
A035 Multi-step Speed Reference 15 Converted value set value (A075) Set value
A101 FI Start Frequency Converted value set value (A075) Set value
A102 FI End Frequency Converted value set value
(A075) Set value
A145
Frequency Addition Amount Setting
Converted value set value (A075) Set value
A220
2nd Multi-step Speed Reference 0
Converted value set value (A075) Set value
A320 RX only: 3rd Multi-step Speed
Reference 0
Converted value set value (A075) Set value
F001
Output Frequency Setting/Monitor
Converted value set value (A075) Set value
d004 PID Feedback Value Monitor Converted value feedback value
(A075)
Feedback value