5 - 19
5 Drive Programming User Variables
Drive Programming User’s Manual (I580-E2)
5-6 Multi-function Input Variables
5
RX only
Function variable Description R/W Reference
SET3 3rd Control R/W C001 to C008 17
CAS Control gain switching R/W C001 to C008 26
PPI P/PI switching R/W C001 to C008 43
ORT Orientation R/W C001 to C008 45
STAT
Pulse train position command input permission
R/W C001 to C008 48
SON Servo ON R/W C001 to C008 54
FOC Preliminary excitation R/W C001 to C008 55
FOT Forward driving stop R/W C001 to C008 71
ROT Reverse driving stop R/W C001 to C008 72
PCNT Pulse counter R/W C001 to C008 74
PCC Pulse counter clear R/W C001 to C008 75