6 Drive Programming Commands
6 - 58
Drive Programming User’s Manual (I580-E2)
6-9 Inverter Control Commands
Run FW
Command Description Argument
Makes the inverter start a forward operation.
This command is a shortcut of the “func value”
command which is previously set as “FW : 1”.
---
Format
Flowchart method Text language method
FW : 1
Run RV
Command Description Argument
Makes the inverter start a reverse operation.
This command is a shortcut of the “func value”
command which is previously set as “RV : 1”.
---
Format
Flowchart method Text language method
RV : 1
Stop FW
Command Description Argument
Makes the inverter decelerate to stop from a for-
ward operation.
This command is a shortcut of the “func value”
command which is previously set as “FW : 0”.
---
Format
Flowchart method Text language method
FW : 0
Stop RV
Command Description Argument
Makes the inverter decelerate to stop from a
reverse operation.
This command is a shortcut of the “func value”
command which is previously set as “RV : 0”.
---
Format
Flowchart method Text language method
RV : 0