A-2 Instructions
SYSMAC CP1L Getting Started Guide 103
Appendix
zAND / AND NOT Instructions
Use for contacts connected in series.
Note There is no limit on the number of contacts that can be connected by AND/AND
NOT instructions.
zOR / OR NOT Instructions
Use for contacts connected in parallel.
Note There is no limit on the number of contacts that can be connected by OR/OR NOT
instructions.
Writing Relay Coils
zOUT / OUT NOT Instructions
OUT instructions turn a relay coil ON when the execution condition is ON. OUT
NOT instructions turn a relay coil OFF when the execution condition is ON.
Note
Do not use coils with the same relay number for OUT and OUT NOT
simultaneously. Doing so will result in a "duplicated coil" program error.
000002
000003
000000
000001
000000
000004
000005
000001
Bus bar
000100
000101
Execution condition
Execution condition