Omron CP1L CPU - A-4-6 Using Servo Drivers for Positioning

Omron CP1L CPU
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A
A-4 CP1L Programming Examples
SYSMAC CP1L Getting Started Guide 137
Appendix
When the PV of the high-speed counter matches target value 2 (3500), interrupt task
05 will be executed.
zDM Area Setup
The comparison table for the CTBL (register comparison table) instruction should
be allocated to DM D600 through D606.
A-4-6 Using Servo Drivers for Positioning
Functions Used
zPulse Output by Built-in Output
Pulse signal outputs from the built-in output of a CPU unit can be used for
positioning and speed control of a servo motor driver with up to 2 axes.
Operation Overview
The following example is for a single-axis handling machine that is used to transfer
product.
Origin search will be executed, followed by positioning operations to points A and B.
Interrupt task
05
Reset "motor run"
Reset "motor stopped"
Reset "motor slow"
P_On
RSET
SET
RSET
100.00
100.01
W0.02
Channel Value Content
D600 0002 Items compared: 2
D601 0BB8 Target value 1: 3000 BCD (BB8 Hex)
D602 0000
D603 0004 Target value 1: Interrupt task No.4
D604 0DAC Target value 2: 3500 BCD (DAC Hex)
D605 0000
D606 0005 Target value 2: Interrupt task No.5
Point B
Point A
Origin
W07E-EN-02+CP1L+GettingStartedGuide.book Seite 137 Montag, 15. September 2008 11:15 11