48
Chapter3 Dimensions
F3SJ-E/B
User’s Manual
Wiring/Installation
Side mounting
Bracket mounting procedure (Mounting) p.67
- If the protective height is more than 1105 mm, use Intermediate Brackets of specified quantities and locations
according to the dimensions. If the brackets described above are not used, ratings and performance cannot be met.
- When you use a sensor in a situation where the sensor is under a load, add an Intermediate Bracket.
12
34.5
Top/Bottom Bracket
(F39-LJB1)
Top/Bottom Bracket
(F39-LJB1)
Intermediate Bracket
(F39-LJB2)
E
[ Unit : mm ]
13.4
34
42
53
42
5.5
30
7
18.3
dia.9
30
19
6.5
7.5
B
A
22.5
D
C (Protective height)
16
46
30
45
<M5 screw fixed> <M8 screw fixed>
19
B
B
E
C
C
E
42
42
5.9 5.9
22 22
4-M5
2-M8
2-M5 2-M5
Dimensions A to E
Dimensions E
* Value E must be 700 mm or less when not using value E obtained from the calculation above.
AC+69
BC+42.2
C 4-digit number of the type name (protective height)
DC-45
E Depends on the protective height. See the table below.
Protective height Number of Intermediate Brackets Dimensions E
0185 to 1105 0 -
1185 to 1345 1 C/2 max.
1425 to 2065 2 C/3 max.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ-E0185P25 and is the answer not in the manual?

Omron F3SJ-E0185P25 Specifications

General IconGeneral
BrandOmron
ModelF3SJ-E0185P25
CategorySecurity Sensors
LanguageEnglish

Related product manuals