Application ExamplesSection 1
1. Partial control of machine
14
G9SX
USER'S GUIDE
Timing chart
(1) Before operation is started.
(2) The processing section cover is opened, and the processing section and the conveyor section stops.
(3) The processing section cover is closed and the processing section and conveyor section restart.
(4) The conveyor section cover is opened and the conveyor section stops.
(5) The transport section cover is closed and the conveyor section restarts.
(6) If the Emergency Stop Switch is pressed, unit A, unit B, and unit C will stop.
G9SX-BC202 (Unit A)
G9SX-AD322-T15 (Unit B:Processing section cover)
G9SX-AD322-T15 (Unit C:Conveyor section cover)
Emergency Stop Switch S1
Reset switch S2
Logical AND output L1
KM1, KM2 NC contact
KM1, KM2 NO contact
KM3, KM4 NC contact
KM3, KM4 NO contact
Operation command
Rotation of motor
Logical AND input T41
Operation command
Rotation of motor
KM5, KM6, NC contact
KM5, KM6, NO contact
Logical AND input T41
Safety Door Switch S4
Safety Door Switch S3
OFF-delay time
OFF-delay time OFF-delay time
OFF-delay timeOFF-delay time
(4)
(3)
(6)
(2)(1)
(5)
Logical AND output L1