2. Functions of each Unit
2-1 Basic Unit
It is possible to connect to other Units by using the logical AND connection output.
■ G9SX-BC@
Safety Inputs
Safety Outputs (Semiconductor Outputs)
Logical AND Connections
Required Settings and Wiring
LED Indicators
Safety inputs 1 input (2-channel input)
Safety input devices
Emergency stop switch, door switch,
light curtain
Instantaneous outputs
2 outputs
OFF-delayed outputs
None
Number of inputs None
Number of outputs 2 outputs
Item G9SX-BC Page
Logical AND connection
input enable/disable
--- ---
Cross fault detection mode ❍ 63
Reset mode ❍ 62
OFF-delay time --- ---
Switching mode --- ---
External indicator fault
diagnosis mode
--- ---
Marking Color Name
PWR Green Power supply indicator
T1 Orange Safety input #1 indicator
T2 Orange Safety input #2 indicator
FB Orange Feedback/reset input indicator
EI Orange Safety output indicator
ERR Red Error indicator
No.
T1 T2
FB
ERREI
PWR
L2L1S24S14
A2X2T22T21
A1X1T12T11
Y1T32 T33T31
G9SX-BC202
24VDC