2. Functions, Wiring and Settings
G9SX
USER'S GUIDE
65
Wiring and SetupSection 3
2-6 OFF-delay Time
The safety output preset time is set using the OFF-delay time preset switch (1 each on the front and back of the
Unit).
Note: 1. Normal operation will occur only if both switches are set to the same setting.
An error will occur if both switches are not identically set.
2. If the preset time is set to 0 seconds, the output function as an instantaneous safety output.
Refer to the following illustration for details on setting switch positions.
1. G9SX-AD322-T15
2. G9SX-AD322-T150
Front Back
Switch
Switch
OFF-DELAY
0.5
0.4
0.3
0.2
15
10
7
5
4
3
2
1.5
1
0.6
0.7
0
OFF-DELAY
0.5
0.4
0.3
0.2
15
10
7
5
4
3
2
1.5
1
0.6
0.7
0
Notch
Example 2: 1-second
OFF-delay
setting
Example 1: 0-second
OFF-delay
setting
40
30
20
10
150
140
130
120
110
100
90
80
70
50
60
0
40
30
20
10
150
140
130
120
110
100
90
80
70
50
60
0
OFF-DELAY OFF-DELAY
Notch
Example 1: 0-second
OFF-delay
setting
Example 2: 70-second
OFF-delay
setting