4. Safety Measures for limited operations
4-1 Manufacturing Flat-panel Displays (Maintenance)
Switching between Normal Operating Mode and Maintenance Mode is performed manually.
In
Normal Operating
Mode, the Safety Door Switch is enabled, and in Maintenance Mode
the Safety Limit Switch is enabled.
Required Units
Unit Qty. Safety input to be applied Page
G9SX-BC 1 Emergency Stop Switch 39
G9SX-GS 1 Door Switch + Limit Switch 44
(1) Emergency
Stop Switch
(3) Conveyor cart
(Safety Limit Switch)
(2) Cover (Safety Door Switch)
(4) Mode selector
(3) Conveyor cart (4) Mode selector(2) Cover
Safety Limit
Switch
D4F
Key-type
Selector Switch
A22K
Safety Door
Switch
D4NS
Safety Guard
Switching Unit
G9SX-GS
Contactor
Basic Unit
G9SX-BC
Logical AND
connection
(1) Emergency
Stop Switch
A22E
Conveyor cart
Emergency Stop Switch
Normal operating mode
Maintenance mode
Cover
Conveyor cart
When pressed, processing will stop.
When the cover is opened, processing will stop.
Emergency Stop Switch
Cover
Conveyor cart
When pressed, processing will stop.
Processing will continue regardless of whether the cover is opened or closed.
Processing will continue regardless of the conveyor cart position.
When the conveyor cart moves away from its safe position, processing will stop.
Manual
switching
Manual