■ Timing chart
(1) In Normal operating mode, the lower unit starts.
(2) Maintenance mode is selected.
(3) The operator opens the door and performs maintenance operation.
(4) The Enabling Switch is gripped to the middle position.
(5) In maintenance mode, the lower unit starts.
(6) When the Enabling Switch is released or gripped, the lower unit stops.
(7) After closing the door and then switching to Normal operating mode, the lower unit will restart.
(8) If the door is opened while in Normal operating mode, the lower unit will stop.
(9) The door is closed, and the lower unit restarts.