■ G9SX-ADA@
Safety Inputs
Safety Outputs (Semiconductor Outputs)
Note: The OFF-delayed outputs can be used as instantaneous outputs by
setting the OFF-delay time to 0 s.
Logical AND Connections
OFF-delay Time Setting
Required Settings and Wiring
LED Indicators
Safety inputs 1 input (2-channel input)
Safety input devices
Emergency stop switch, door switch,
light curtain
Instantaneous outputs
2 outputs
OFF-delayed outputs
2 outputs
Number of inputs 2 inputs
Number of outputs 2 outputs
G9SX-ADA222-T15-@ 0 to 15 s
G9SX-ADA222-T150-@ 0 to 150 s
Item G9SX-ADA Page
Logical AND connection
input enable/disable
❍ 57
Cross fault detection mode ❍ 63
Reset mode ❍ 62
OFF-delay time ❍ 65
Switching mode --- ---
External indicator fault
diagnosis mode
--- ---
Marking Color Name
PWR Green Power supply indicator
T1 Orange Safety input #1 indicator
T2 Orange Safety input #2 indicator
FB Orange Feedback/reset input indicator
AND1 Orange Logical AND input indicator
AND2 Orange Logical AND input indicator
EI Orange Safety output indicator
ED Orange
OFF-delayed safety output
indicator
ERR Red Error indicator