EasyManua.ls Logo

Omron G9SX - Page 59

Omron G9SX
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Functions, Wiring and Settings
G9SX
USER'S GUIDE
59
Wiring and SetupSection 3
(5 ) Two logical AND connection outputs, each from different Advanced/Basic Units, can be logical AND connected
to a single G9SX-ADA Unit.
(6 ) The largest possible system configuration contains a total of 20 Advanced and Basic Units. In this configuration,
each Advanced Unit can have up to five Expansion Units.
Note: The section on Advanced Units, above, can also be replaced with G9SX-NS/-NSA/-GS.
G9SX-BC G9SX-BC
G9SX-ADA
Number of Units connected
per logical AND output:
4 Units max.
Total number of Units
connected by logical AND:
20 Units max.
Number of Units connected
in series by logical AND:
5 Units max.
Note 1: Basic Unit = G9SX-BC
Advanced Unit = G9SX-AD or G9SX-ADA
Note 2: The G9SX-AD322-T-@ has only one logical AND
output.
Advanced Unit
or Basic Unit
Advanced UnitAdvanced Unit Advanced Unit
Advanced Unit
Advanced Unit Advanced Unit Advanced Unit
Advanced Unit
Advanced Unit Advanced Unit Advanced Unit
Advanced Unit Advanced Unit Advanced Unit
Advanced Unit
Advanced Unit Advanced Unit Advanced Unit
Advanced Unit

Table of Contents

Related product manuals