216
Terminal Commands
Section 6-6
Description System menu is displayed when “display permitted” is set, and from the system
menu, selection of transmit mode or maintenance mode is possible. If “display
inhibited” is set, the system menu is not displayed.
Turning off the power or resetting operation validates the settings made with the
DIP switch (SW2-3) on the NT20S.
6-6 Terminal Commands
This section describes the terminal commands used to display character strings or
graphics in accordance with instructions from the host, independently of the
screens registered in the NT20S.
Terminal commands designate screen attributes such as inversion, flashing, cur-
sor position and size of characters before the characters are displayed.
Once screen attributes are set, they remain effective for screen displays until they
are cancelled or other attributes are set.
In addition, continuous lines and circles can be drawn.
Clear Screen
Format
1B
[ESC]
26
&
Description Clears all text and graphics on the NT20S screen.
Reference: Even if this command is used to clear a screen, the NT20S still displays the pre-
ceding screens.
After the display of number, text, lamps or touch switches is upgraded, only the
upgraded parts are re-displayed.