To import all variables with a Network Publish attribute, click the Y
es Button. To import only
some of these variables, click the No Button.
After you import the variables to the tags, click the Y
es Button to automatically create tag sets,
or click the No Button to set up tag sets manually.
If you select the Y
es Button in the previous step, the variables will be imported as shown below
on the Tag Sets Tab Page. Each variable will be imported into a separate tag set and the de-
vice parameters will be automatically edited. (The variable name will be used for the tag set
name.)
7 Tag Data Link Functions
7-34
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)