Units with Ground Terminals and Type of Ground Terminals
Functional Grounding
Input terminal block
CPU Unit
NX Unit
Functional
Grounding
l
Units with Ground Terminals
CPU Unit
Additional NX Unit Power Supply Unit
Shield Connection Unit
Grounding type Symbol Function
Functional
Grounding
Functional grounding is done to protect device and system functions, in-
cluding prevention of noise from external sources, or prevention of noise
from devices or equipment that could have harmful effects on other devi-
ces or equipment.
DIN Track Contact Plates
A Unit that has a ground terminal also has a DIN Track contact plate on the back of the Unit.
The DIN Track contact plate is connected internally to the ground terminal on the Unit.
This means that the ground terminal will be electrically connected to the DIN T
rack.
5 Installation and Wiring
5-46
NX-series NX1P2 CPU Unit Hardware Users Manual (W578)