GRT1-CP1-L Positioning Unit Section 7-5
3. Set the items in the dialog box as shown in the following table.
The above settings are stored in non-volatile memory. If a setting is changed,
the Positioning Unit must be reset before the new setting will be valid.
Setting Digital Input
Functions
A Positioning Unit supports one digital input. Use the following procedure to
set functionality. To set the functionality of the digital input rising and falling
edges, refer to the General Tab Page on page 265.
1,2,3... 1. Click the IN Tab in the Edit Unit Parameters Window to display the IN Tab
Page shown below.
2. Select the digital input (No. 00) and click the Edit Button. The Edit Termi-
nal Dialog Box will be displayed.
Item Description
I/O Comment Enter a comment for the digital output.
Detection Mode Specify whether to keep track of the total ON time (unit: s) or
number of contact operations (unit: operations) for the main-
tenance counter of the digital output.
Value Enter the set value for the detection mode.
The value can be set to between 0 and 4,294,967,295 oper-
ations for the number of contact operations and to between
0 and 4,294,967,295 seconds for the total ON time.