Regular Payload Series-Hardware Installation Manual TM5 Series 53
5.6 Control Box Power Interface and Robot Interface
5.6.1 Control Box Power Interface
TM5-700 / TM5-900:
The power cable of the control box has an IEC plug. The local power plug is connected to the IEC plug.
TM5M-700/ TM5M-900:
The power cable of the control box has Hirose (HRS) DF60 series connector.
The power supply should be equipped with the following:
• Grounding
• Main fuse
• Residual current device (RCD)
It is recommended to install a master switch on the equipment power supply for robot applications for
servicing and inspection.
AC Adapter
AC Adapter:IEC plug
DC IN Power Connector:( HRS)DF60-3EP-10.16C
DC IN for External Power Supply Connector: Contact OMRON for purchasing
External Power Supply Remote Control Connector:Contact OMRON for
purchasing
DC IN Power
External Power Supply Remote Control
DC IN for External Power Supply
- +
TM5M-700/ TM5M-900
TM5-700 / TM5-900