EasyManua.ls Logo

Omron TM5 Regular Payload Series

Omron TM5 Regular Payload Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Regular Payload Series-Hardware Installation Manual TM5 Series 53
5.6 Control Box Power Interface and Robot Interface
5.6.1 Control Box Power Interface
TM5-700 / TM5-900:
The power cable of the control box has an IEC plug. The local power plug is connected to the IEC plug.
TM5M-700/ TM5M-900:
The power cable of the control box has Hirose (HRS) DF60 series connector.
The power supply should be equipped with the following:
Grounding
Main fuse
Residual current device (RCD)
It is recommended to install a master switch on the equipment power supply for robot applications for
servicing and inspection.
AC Adapter
AC AdapterIEC plug
DC IN Power Connector:( HRSDF60-3EP-10.16C
DC IN for External Power Supply Connector Contact OMRON for purchasing
External Power Supply Remote Control ConnectorContact OMRON for
purchasing
DC IN Power
External Power Supply Remote Control
DC IN for External Power Supply
- +
TM5M-700/ TM5M-900
TM5-700 / TM5-900