EasyManuals Logo

Opengear ACM5000 User Manual

Opengear ACM5000
335 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #252 background imageLoading...
Page #252 background image
Chapter 14: Command Line Configuration
252 Console Server & RIM Gateway User Manual
Add power device host
To add a UPS/RPC network host with the following details:
IP address/ DNS name 192.168.2.5
Host name remoteUPS
Description UPSroom3
Type UPS
Allowed services ssh port 22 and https port 443
Log level for services 0
Issue the commands below:
# config -s config.sdt.hosts.host4.address=192.168.2.5
# config -s config.sdt.hosts.host4.name=remoteUPS
# config -s config.sdt.hosts.host4.description=UPSroom3
# config -s config.sdt.hosts.host4.device.type=ups
# config -s config.sdt.hosts.host4.tcpports.tcpport1=22
# config -s config.sdt.hosts.host4.tcpports.tcpport1.loglevel=0
# config -s config.sdt.hosts.host4.udpports.udpport2=443
# config -s config.sdt.hosts.host4.udpports.udpport2.loglevel=0
The loglevel can have a value of 0 or 1.
The default services that should be configured are: 22/tcp (ssh), 23/tcp (telnet), 80/tcp (http), 443/tcp (https), 1494/tcp
(ica), 3389/tcp (rdp), 5900/tcp (vnc)
Add other network host
To add any other type of network host with the following details:
IP address/ DNS name 192.168.3.10
Host name OfficePC
Description MyPC
Allowed sevices ssh port 22,https port 443
log level for services 1
Issue the commands below. If the Host is not a PDU or UPS power device or a server with IPMI power control then leave
the device type blank:
# config -s config.sdt.hosts.host4.address=192.168.3.10
# config -s config.sdt.hosts.host4.description=MyPC
# config -s config.sdt.hosts.host4.name=OfficePC
# config -s config.sdt.hosts.host4.device.type='' (leave this value blank)
# config -s config.sdt.hosts.host4.tcpports.tcpport1=22
# config -s config.sdt.hosts.host4.tcpports.tcpport1.loglevel=1
# config -s config.sdt.hosts.host4.udpports.tcppport2=443
# config -s config.sdt.hosts.host4.udpports.tcpport2.loglevel=1
If you want to add the new host as a managed device, make sure to use the current total number of managed devices + 1,
for the new device number.
To get the current number of managed devices:
# config -g config.devices.total
Assuming we already have one managed device, our new device will be device 2. Issue the following commands:
# config -s config. devices.device2.connections.connection1.name=192.168.3.10
# config -s config. devices.device2.connections.connection1.type=Host
# config -s config. devices.device2.name=OfficePC
# config -s config. devices.device2.description=MyPC