Chapter 14: Command Line Configuration
258 Console Server & RIM Gateway User Manual
Assume this is our second alert, and we want to send alert emails to john@opengear.com and sms's to
peter@opengear.com:
# config -s config.alerts.alert2.description=MySecondAlert
# config -s config.alerts.alert2.email=john@opengear.com
# config -s config.alerts.alert2.email2=peter@opengear.com
To use NAGIOS to notify of this alert
# config -s config.alerts.alert2.nsca.enabled=on
To use SNMP to notify of this alert
# config -s config.alerts.alert2.snmp.enabled=on
Increment the total alerts:
# config -s config.alerts.total=2
Below are the specific settings depending on the type of alert required:
Connection Alert
To trigger an alert when a user connects to serial port 5 or network host 3:
# config -s config.alerts.alert2.host3='host name'
# config -s config.alerts.alert2.port5=on
# config -s config.alerts.alert2.sensor=temp
# config -s config.alerts.alert2.signal=DSR
# config -s config.alerts.alert2.type=login
Signal Alert
To trigger an alert when a signal changes state on port 1:
# config -s config.alerts.alert2.port1=on
# config -s config.alerts.alert2.sensor=temp
# config -s config.alerts.alert2.signal=[ DSR | DCD | CTS ]
# config -s config.alerts.alert2.type=signal
Pattern Match Alert
To trigger an alert if the regular expression '.*0.0% id' is found in serial port 10's character stream.
# config -s "config.alerts.alert2.pattern=.*0.0% id"
# config -s config.alerts.alert2.port10=on
# config -s config.alerts.alert2.sensor=temp
# config -s config.alerts.alert2.signal=DSR
# config -s config.alerts.alert2.type=pattern
UPS Power Status Alert
To trigger an alert when myUPS (on localhost) or thatUPS (on remote host 192.168.0.50) power status changes between
on line, on battery and low battery.
# config -s config.alerts.alert2.sensor=temp
# config -s config.alerts.alert2.signal=DSR
# config -s config.alerts.alert2.type=ups
# config -s config.alerts.alert2.ups1=myUPS@localhost
# config -s config.alerts.alert2.ups2=thatUPS@192.168.0.50
Environmental and Power Sensor Alert

Table of Contents