EasyManua.ls Logo

Opticon OPI-3601 - 6.2. Aiming Pattern; 6.3. Imaging Range

Opticon OPI-3601
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPI-3601
Specifications Manual
8
6.2. Aiming Pattern
The aiming is used for the following purpose:
1. Fill light to recognize the appropriate reading range.
2. Fill light when auto trigger is used.
The aiming specifications are as follows:
- An optical axis of imaging field of view and the center of horizontal aiming width coincide at a
distance of L=85±20 mm from the front edge of the scanner.
- The horizontal aiming width to the horizontal width of imaging filed of view at a distance of L=85
is 80%±10%.
Figure 3: Aiming Pattern and Imaging Range
6.3. Imaging Range
The range is ±5% from the following values.
L: Distance from the front edge of scanner
[mm] 60 80 100 120 140 160
H: Horizontal imaging range
[mm] 66 82 97 111 125 136
V: Vertical imaging range
[mm] 42 52 62 72 82 93