EasyManua.ls Logo

Opticon OPI-3601 - 6.2. Aiming Pattern; 6.3. Imaging Range

Opticon OPI-3601
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPI-3601
Specifications Manual
8
6.2. Aiming Pattern
The aiming is used for the following purpose:
1. Fill light to recognize the appropriate reading range.
2. Fill light when auto trigger is used.
The aiming specifications are as follows:
- An optical axis of imaging field of view and the center of horizontal aiming width coincide at a
distance of L=85±20 mm from the front edge of the scanner.
- The horizontal aiming width to the horizontal width of imaging filed of view at a distance of L=85
is 80%±10%.
Figure 3: Aiming Pattern and Imaging Range
6.3. Imaging Range
The range is ±5% from the following values.
L: Distance from the front edge of scanner
[mm] 60 80 100 120 140 160
H: Horizontal imaging range
[mm] 66 82 97 111 125 136
V: Vertical imaging range
[mm] 42 52 62 72 82 93