EasyManua.ls Logo

Opticon OPI-3601 - Auto Trigger Detection; Motion Tolerance

Opticon OPI-3601
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPI-3601
Specifications Manual
15
7.8.2. Auto Trigger Detection
Trigger is enabled when inserting a gray-colored paper on a black backing paper.
Trigger is also enabled when inserting a black-colored paper on a gray backing paper.
<Conditions>
Paper used : Black paper from Glory called as Black 010010016
: Gray paper from Glory called as Silver-gray 010010016
Ambient Light : 500 ~ 1000 lux
Moving Speed of Detected Paper : 2 m/second or slower
Ambient Temperature and Humidity : Room temperature and room humidity
Figure 9: Auto Trigger
7.8.3. Motion Tolerance
UPC 100% can be read when it is moving at 2m/s.
<Conditions>
Ambient Temperature and Humidity : Room temperature and Room humidity
Ambient Light : 500 ~ 1000 lux
Distance : 105mm from the front edge of the scanner
PCS (1D and 2D) : 0.9 or higher
Bar Code Sample : Refer to Chapter 7.1.
Figure 10: Motion Tolerance
Note: Scanning may fail due to the specular reflection of LED illumination when the reflectivity is
high.

Table of Contents

Related product manuals