No. SX-DSV02472 -117-
(2) Warning types
General warning
Warning
No.
(Hex.)
Warning Content
Pr 4.40/
Pr 4.41
*1)
Pr 6.38
Corresponding
bit
Load factor is 85% or more the protection level.
A1
Over-regeneration
Regenerative load factor is 85% or more the
2 bit 5
Battery voltage is 3.2 V or lower.
Fan has stopped for 1 sec.
A4
Encoder
communication
The number of successive encoder
communication errors exceeds the specified
5 bit 4
A5
Encoder overheat
The encoder detects overheat warning.
6 bit 3
A6
Oscillation
detection warning
If Pr6.37 (oscillation detection level) is
non-zero, it is detected that the torque
oscillation (oscillation state) than that specified
7 bit 13
A7
Lifetime detection
Life expectancy of capacitor or fan becomes
8 bit 2
A8
External scale error
warning
The external scale detects the warning.
9 bit 8
A9
External scale
communication
warning
The number of successive external scale
communication errors exceeds the specified
value.
10 bit 14
Extended warning
Warning
No.
(Hex.)
Warning Content
Output
Waning mask
Pr 4.40/
Pr 4.41
*1)
Pr 6.38
Corresponding
bit
C3
Main power off
warning
When setting of Pr7.14 (Main power off
warning detection time) is 10-1999,
instantaneous power interruption occurs
between L1 and L3 and lasts for a time longer
than the setting of Pr7.14.
14 bit 12
R1.05
Motor Business Division, Appliances Company, Panasonic Corporation