INF-14
SECTION 1 SERVICE INFORMATION
<RZ31K/RS30K>
SELF CHECK 1/3
MODEL : RZ31K
SERIAL NO. : SW1234567890
---------- VERSION --------------
MAIN : 1.00.00
SUB : 1.00.00
DIGITAL LINK : 1.30.20.5
FPGA : 01.01/02.02/03.03
CPLD : 01.01
FM(R) : 00.0400.00
FM(G) : 00.0400.00
FM(B) : 00.0400.00
LD DRIVER : 01.00/01.00/01.00/01.00
DEVICE CHECK : OK
SELF CHECK 2/3
LD SUB : 01.00/01.00/01.00/01.00
FRC : 1.00.00
POWER : 1.00.00
---------- DEVICE CHECK ----------
OK : AIR TEMP 123/456
OK : DMD TEMP 123/456
OK : OUT TEMP 123/456
OK : AIR FLOW 123/456/789
OK : LD1B TEMP 123
NG : LD1S TEMP 123
OK : LD2B TEMP 123
OK : LD2S TEMP 123
DEVICE CHECK : NG
SELF CHECK 3/3
OK : FPGA TEMP 123
OK : LD1B 1 * 0 1 1 1
OK : LD1S 1 0 1 1 1 *
OK : LD2B 1 1 1 1 1 1
OK : LD2S 1 1 1 1 1 1
NG : FAN[1] 1111 1110 1111 1111 1111
OK : FAN[2] 1111 1111 1111 1111 1
OK : PHOTO Y 123456.7
OK : ATM 1234/567
OK : ANGLE H -123.4/ V +123.4
OK : SHUTTER 65535 [ 0]
DEVICE CHECK : NG
2. 3DCMS
• Setting of the 3D Color Management System operation.
- ON : Enable the 3D Color Management system function. (Default setting)
- OFF : Disable the 3D Color Management system function.
3. SELF CHECK
• Self-diagnosing information Displays.
– Model name
– Serial no.
------------------- VERSION-----------------------------
– Main CPU rmware version
– Sub CPU rmware version
– Digital Link rmware version
– Digital Link rmware version
– FPAG rmware version
– (R/G/B) Formatter rmware version
– LD driver (LD1B/LD1S/LD2B/LD2S) rmware version
– LD Sub driver rmware version
– FRC rmware version
– Power rmware version
------------------- DEVICE CHECK-----------------------------
– Intake air temperature (Celsius/Fahrenheit)
– DMD temperature (Celsius/Fahrenheit)
– Exhaust air temperature (Celsius/Fahrenheit)
Airow sensor
(Sensor value/AD conversion value/Correc-
tion value)
– LD1B temperature (Celsius)
– LD1S temperature (Celsius)
– LD2B temperature (Celsius)
– LD2S temperature (Celsius)
– FPGA temperature (Celsius)
LD1B check
(1: normal / 0: abnormal / *: intentional Off)
LD1S check
(1: normal / 0: abnormal / *: intentional Off)
LD2B check
(1: normal / 0: abnormal / *: intentional Off)
LD2S check
(1: normal / 0: abnormal / *: intentional Off)
Fan[1] check
(1: normal / 0: abnormal)
Fan[2] check
(1: normal / 0: abnormal)
– Luminance sensor check (detected value)
Atmospheric pressure sensor check
(Sensor detected
value/Temperature detected value)
– Angle sensor check (Horizontal angle / Vertical angle)
Shutter control check (Opening and shutting times
[Failure times])
– Device check (OK: Normal, NG: abnormal)
[Note]
Items to indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormality now. If the
"OK" indicates in red, the projector had an abnormality in the past and operates normally now.
To clear the error status, press the [MENU] key in the SELF CHECK mode, the confirmation window will appear and select
[OK] to clear.
CLEAR ERROR INFOMATION?
OK C ANCEL
• This must be done after finishing the repair or maintenance.

Table of Contents

Related product manuals