EasyManua.ls Logo

Panasonic PT-RS30K

Panasonic PT-RS30K
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INF-15
SECTION 1 SERVICE INFORMATION
<RZ31K/RS30K>
l How to read the status of light source
LD1B check
(1: normal / 0: abnormal / *: intentional Off)
OK LD1B 1 * 0 1 1 1
LD1B-1
LD1B-2
LD1B-3
LD1B-4
LD1B-5
LD1B-6
LD1S check
(1: normal / 0: abnormal / *: intentional Off)
OK LD1S 1 0 1 1 1 *
LD1S-1
LD1S-2
LD1S-3
LD1S-4
LD1S-5
LD1S-6
LD2B check
(1: normal / 0: abnormal / *: intentional Off)
OK LD2B 1 * 0 1 1 1
LD2B-1
LD2B-2
LD2B-3
LD2B-4
LD2B-5
LD2B-6
LD2S check
(1: normal / 0: abnormal / *: intentional Off)
OK LD2S 1 0 1 1 1 *
LD2S-1
LD2S-2
LD2S-3
LD2S-4
LD2S-5
LD2S-6
LD2S-3LD2S-6
LD1S-3LD1S-6
LD2S-2LD2S-5
LD1S-2LD1S-5
LD2S-1LD2S-4
LD1S-1LD1S-4
LD2B-1 LD2B-4
LD2B-2 LD2B-5
LD2B-3 LD2B-6
LD1B-1 LD1B-4
LD1B-2 LD1B-5
LD1B-3 LD1B-6
l Each LD bank location
* Intentional Off
If one of the laser device has an open failure for blue or yellow light, the projector cuts off
the other laser device intentionally to maintain the proper white balance. It will return the
normal operation when the LD bank which has an open failure device actually is replaced
with new one.

Table of Contents