INF-16
SECTION 1 SERVICE INFORMATION
<RZ31K/RS30K>
l How to read the status of fans
㉖
– Fan[1] check
(1: normal / 0: abnormal)
NG FAN[1] 1111 1110 1111 1111 1111
Radiator 1
Radiator 2
Radiator 3
Radiator 4
Radiator 5
Radiator 6
Radiator 7
Radiator 8
Radiator 9
Radiator 10
Radiator 11
Radiator 12
Exhaust 1
Exhaust 2
Exhaust 3
Exhaust 4
Intake 1
Intake 2
Color prism 1
Color prism 2
㉗– Fan[2] check
(1: normal / 0: abnormal)
NG FAN[2] 1111 1110 1111 1111 1
Color prism 3
Color prism 4
Engine exhaust 1
PW 1
PW 2
Circuit intake 1
Circuit intake 2
LD driver 1
LD driver 2
Engine exhaust 2
Pump 1
Pump 2
Pump 3
Pump 4
Pump 5
Pump 6
Pump 7
l Fans location
Fan/Pump error
No. of error
detection
Projector operation
Cooling fans
1 pce Decrease the LD output and keep projector-on.
more than 2 pcs Shutdown
DMD radiator pump (Pump 1 to 3) 1 pce Shutdown
LD radiator pump (Pump 4 to 7) 1 pce Shutdown
l Fan/Pump error and projector operation
Exhaust 1 fan
Exhaust 3 fan
Radiator intake 7 ~12 fans
Intake 2 fan
Intake 1 fan
Radiator intake 1 ~6 fans
Exhaust 2 fan
Exhaust 4 fan
PW 1 fan
PW 2 fan
Color prism 2 fan
Color prism 3 fan
Color prism 1 fan
Color prism 4 fan
Circuit intake 2 fan
Circuit intake 1 fan
LD driver 2 fan
LD driver 1 fan
Engine exhaust 1 fan
Engine exhaust 2 fan