INF-37
SECTION 1 SERVICE INFORMATION
<RZ31K/RS30K>
Chapter 6Maintenance Light source/temperature/lter indicators
194 - ENGLISH
Temperature indicator <TEMP>
Indicator status Status Solution
Lighting in red
f Warm-up status
f Wait ve minutes when the power is turned on while the temperature is low
(approximately 0 °C (32 °F)).
f Install the projector in a location with the operating environment temperature
between 0 °C (32 °F) and 50 °C (122 °F)
*1
.
f Internal temperature is high
(warning).
f Remove any objects if they are blocking the air intake/exhaust port.
f Install the projector in a location with the operating environment temperature
between 0 °C (32 °F) and 50 °C (122 °F)
*1
, and ambient humidity between
10 % and 80 % (no condensation).
f Perform maintenance
*2
or replace the lter if the lter indicator <FILTER>
lights up.
Blinking in red
(2 times)
f Internal temperature is high (standby
status).
Blinking in red
(3 times)
f The cooling fan has stopped.
f Turn the <MAIN POWER> switch to <OFF> .
*1 The operating environment temperature should be between 0 °C (32 °F) and 45 °C (113 °F) if the projector is used at an altitude between 1 400 m
(4 593') and 4 200 m (13 780') above sea level. However, when the [PROJECTOR SETUP] menu [OPERATION SETTING] [OPERATING
MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3], the operating environment temperature should be between 0 °C (32 °F) and 45 °C
(113 °F), and when the Smoke Cut Filter is used, it should be between 0 °C (32 °F) and 40 °C (104 °F), regardless of the altitude.
When the [PROJECTOR SETUP] menu [OPERATION SETTING] [OPERATING MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG
LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level. When the Smoke Cut Filter is used, the projector
cannot be used at an altitude of 1 400 m (4 593') or higher above sea level.
*2 Maintenance of the Smoke Cut Filter is not possible. Replace with new one.
Note
f If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
Filter indicator <FILTER>
r When the air lter unit/Replacement Filter Unit (Model No.: ET‑EMF330) is attached
Indicator status Status Solution
Lighting in red
f The lter is clogged.
f The runtime of the lter exceeds the
recommended time to replace the
lter.
f The temperature around or outside
the projector is abnormally high.
f Perform maintenance or replacement of the lter in the following cases.
g The filter is dirty.
g The recommended time to replace the filter has been exceeded.
f Remove any objects if they are blocking the air intake/exhaust port.
f Do not use the projector at an altitude of 4 200 m (13 780')
*1
or higher
above sea level.
Blinking in red
f The air lter unit is not attached.
f The Long Life Filter Unit or Smoke
Cut Filter is not attached.
f Attach the air lter unit/Replacement Filter Unit.
*1 When the [PROJECTOR SETUP] menu [OPERATION SETTING] [OPERATING MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG
LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level.
r When the Long Life Filter Unit (Model No.: ET-EMFU330) is attached
Indicator status Status Solution
Lighting in red
f The lter is clogged.
f The runtime of the lter exceeds the
recommended time to replace the
lter.
*1
f The temperature around or outside
the projector is abnormally high.
f Perform maintenance or replacement of the lter in the following cases.
g The filter is dirty.
g The recommended time to replace the filter has been exceeded.
*1
f Remove any objects if they are blocking the air intake/exhaust port.
f Do not use the projector at an altitude of 4 200 m (13 780')
*2
or higher
above sea level.
Blinking in red f [FILTER TYPE]
*3
is set to [NORMAL]. f Set [FILTER TYPE]
*3
to [LONG LIFE].
*1 If the following two conditions are fullled, the recommended time to replace the lter is not set.
f The [PROJECTOR SETUP] menu [OPERATION SETTING] [OPERATING MODE] is set to anything other than [HIGH].
f The [PROJECTOR SETUP] menu [FILTER SETTING] [FILTER TYPE] is set to [LONG LIFE].
*2 When the [PROJECTOR SETUP] menu [OPERATION SETTING] [OPERATING MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG
LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level.
*3 [FILTER TYPE] can be set in the [PROJECTOR SETUP] menu [FILTER SETTING] [FILTER TYPE].
Chapter 6Maintenance Light source/temperature/lter indicators
ENGLISH - 193
Light source/temperature/lter indicators
When an indicator lights up
If a problem occurs inside the projector, the light source indicators <LIGHT1>/<LIGHT2>, temperature indicator
<TEMP>, or lter indicator <FILTER> will inform you by lighting or blinking in red. Check the status of the
indicators and take following measures.
Attention
f When switching off the projector to deal with problems, make sure to follow the procedure in “Switching off the projector” .
Light source indicator <LIGHT1>
Light source indicator <LIGHT2>
Temperature indicator <TEMP>
Filter indicator <FILTER>
Light source indicators <LIGHT1>/<LIGHT2>
Indicator status Status Solution
Lighting in red
f Some of the elements of the light
source are defective and the light
output has decreased.
f Turn the <MAIN POWER> switch to <OFF> , and turn on the
power again.
Blinking in red
(1 time)
f The light source is turned off since
the projection lens cannot be
detected.
f Turn off the power and mount the projection lens again.
f Turn the <MAIN POWER> switch to <OFF> , and turn on the
power again.
Blinking in red
(2 times)
f The light source does not light up,
or the light source turns off while the
projector is in use.
f Turn the <MAIN POWER> switch to <OFF> , and turn on the
power again.
Blinking in red
(3 times)
Note
f If the light source indicators <LIGHT1>/<LIGHT2> are still lit or blinking after taking the measures, set the <MAIN POWER> switch to
<OFF>, and ask your dealer for repairs.
f The light source indicator corresponding to the light source being lit will light up in green if the projector is in projection mode and there is no
indication of problem by lighting or blinking in red.