Technical Specications 7-2
Selection of Dynamic Braking Resistance and Fuses (IP66 units)
IP66 Units Dynamic Brake Resistor Info Fuse Info
Supply Part number
kW
Efci-
ency
Input Current (A)
Output
Current
(A)
Input
protection
current
Min
ohms
Peak
A
Cont.
A
Power
kW
Sugges-
ted
Resistor
Model
Current
rating
230V
380V/
460V
460V/
480V
1 ph
220V
16G-11-0025-XX 0.37 94% 5.8 2.5 10
60 10 5 0.2 80
JJS-15 15A
16G-11-0045-XX 0.75 94% 10 4.5 18.1
16G-11-0070-XX 1.5 94% 14 7 25.2
JJS-25 25A
16G-11-0100-XX 2.2 94% 20 10 32
3 ph
220V
16G-31-0025-XX 0.37 94% 3.5 2.5 8.2 60 10 5
0.2 80
JJS-15 15A
16G-31-0045-XX 0.75 94% 5.4 4.5 11.5
50 15 7.5
16G-31-0070-XX 1.5 94% 7.8 7 18.2
JJS-25 25
16G-31-0100-XX 2.2 94% 11 10 21.5
3 ph
460V
16G-41-0020-XX 0.75 94% 3 2.1 2 7
120 10 5
0.1 145
JJS-15 1516G-41-0040-XX 1.5 94% 5 4.2 4 11
0.15
95
16G-41-0065-XX 2.2 94% 7.5 7.0 6.5 15
16G-42-0090-XX 4 94% 11 9.2 9 21
100 15 7.5
0.4
JJS-30 30
16G-42-0120-XX 5.5 94% 14 11.5 12 29 0.55
16G-42-0170-XX 7.5 94% 18.5 16 17 34 0.75 JJS-45 45
16G-42-0230-XX 11 97% 24 21 23 47 50 25 12.5 1.1 60 JJS-60 60
16G-43-0320-XX 15 97% 36.5 27 32 80
35
40 20 1.5
35
JJS-80 80
16G-43-0380-XX* 18.5 97% 44 31 38 90
50
25
2 JJS-90 90
16G-43-0440-XX* 22 97% 51 35 44 100 2.2 JJS-100 100
16G-44-0600-XX* 30 97% 70 53 60 110
25 32
3
25
AJT-125 125
16G-44-0750-XX* 37 97% 80 64 75 120 4 AJT-150 150
16G-45-0900-XX* 45 97% 94 75 90 150
18 75 45
4.5
18
AJT-200 200
16G-45-1100-XX* 55 98% 120 85 110 180 5.5 AJT-200 200
16G-45-1500-XX* 75 98% 160 115 150 240 16 100 50 7.5 16 AJT-300 300
16G-46-1800-XX* 90 98% 190 130 180 285 9 150 88 9 9 AJT-350 350
* Not UL listed

Other manuals for Parker AC10 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker AC10 series and is the answer not in the manual?

Parker AC10 series Specifications

General IconGeneral
Overload Capacity150% for 60 seconds
Analog Inputs2
Analog Outputs1
Communication OptionsModbus RTU
Protection RatingIP20
Input Voltage200-240VAC, 380-480VAC, 500-575VAC, 600VAC, 690VAC
Digital Outputs2
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Operating Temperature-10°C to +50°C
Humidity5% to 95% (non-condensing)
DimensionsVaries by model
WeightVaries by model
BrakingBuilt-in dynamic braking

Related product manuals