Requirements
IMPORTANT: Please read this information BEFORE installing the equipment.
WARNING – Operation of this equipment requires detailed installation and operation instructions provided in the
Installation/Operation manual intended for use with this product. This information is provided on the CD ROM, oppy
diskette(s), or other storage devise included in the container this device was packaged in. It should be retained with this
device at all times. A hard copy of this information may be ordered from the supplier indicated on the product label.
Intended Users
This leaet is to be made available to all persons who are required to install, congure or service equipment described
herein, or any other associated operation.
The information given is intended to highlight safety issues, EMC considerations, and to enable the user to obtain
maximum benet from the equipment.
Application Area
The equipment described is intended for industrial motor speed control utilizing AC induction motors or AC synchronous
machines.
Personnel
Installation, operation and maintenance of the equipment should be carried out by competent personnel. A competent
person is someone who is technically qualied and familiar with all safety information and established safety practices;
with the installation process, operation and maintenance of this equipment; and with all the hazards involved.
Product Warnings
DANGER Risk of electric shock
Attention – Hot surfaces
Caution Refer to documentation
Earth/Ground Protective Conductor Terminal
Hazards
DANGER! - Ignoring the following may result in injury
1. This equipment can endanger life by exposure to rotating machinery and high voltages.
2. The equipment must be permanently earthed due to the high earth leakage current, and the drive
motor must be connected to an appropriate safety earth.
3. Ensure all incoming supplies are isolated before working on the equipment. Be aware that there
may be more than one supply connection to the drive.
4. There may still be dangerous voltages present at power terminals (motor output, supply input
phases, DC bus and the brake, where tted) when the motor is at standstill or is stopped.
5. For measurements use only a meter to IEC 61010 (CAT III or higher). Always begin using the
highest range. CAT I and CAT II meters must not be used on this product.
6. Allow at least 5 minutes (20 minutes for above 30kW) for the drive's capacitors to discharge to
safe voltage levels (<50V). Use the specied meter capable of measuring up to 1000V dc & ac rms to
conrm that less than 50V is present between all power terminals and earth.
7. Unless otherwise stated, this product must NOT be dismantled. In the event of a fault the drive
must be returned. Refer to "Routine Maintenance and Repair".
8. WARNING – The opening of the branch-circuit protective device may be an indication that a fault
current has been interrupted. To reduce the risk of re or electric shock, current-carrying parts and
other components of the controller should be examined and replaced if damaged.
Introduction
This manual offers an introduction to the installation and connection for the AC10 series.
Parameters setting, software, and operation are also covered in this document. For
complete instructions, please refer to the Product Installation Manual, available online at
www.parker.com/ssdusa/ac10
1-1 Introduction - Requirements - Product Warnings