APPENDIX B
110 IPA Hardware Installation Guide
The R7-1 with 5um magnetic would be set to 8000 counts/electrical pitch. Note that the halls are inverted for
both IForce and Ripped series coils for IPA configuration.
Standard resolutions are listed below:
Motor Series
5um
1um
0.5um
0.1um
110 / 210 / 310
12192
60960
121920
609600
410
17068
85340
170680
853400
ML50
12000
60000
120000
600000
R7
8000
40000
80000
400000
R10 / R16
12000
60000
120000
600000
This sets the number of encoder counts (post-quad) over one electrical pitch (two magnet widths on the track).
This number can be calculated by the electrical pitch divided by the post-quadrature resolution. i.e., 60.96mm /
5um / post-quad pulse = 12192 post-quad pulses / pitch
The motor rated speed can be used to limit maximum speed commanded for higher resolution encoders. Below
are the maximum speeds for the standard positioner encoder options.
B
5um
LME
A
1um
LME
Q
5um
Renishaw
L
1um
Renishaw
M
0.5um
Renishaw
P
0.1um
Renishaw
Max Speed (m/s)
7
2.5
5
5
3
0.4

Table of Contents