Insulation
Terminal Voltage
Range
Resolution
Accuracy
Test Current
Short circuit
current
125V
(0%~+10%)
0.125~4.000 MΩ
0.001MΩ
+(2%+10dgt)
1mA
@load125kΩ
1mA
4.001~40.00 MΩ
0.01MΩ
+(2%+10dgt)
40.01~400.0 MΩ
0.1MΩ
+(4%+5dgt)
400.1~1000 MΩ
1MΩ
+(5%+5dgt)
250V
(0%~+10%)
0.250~4.000 MΩ
0.001MΩ
+(2%+10dgt)
1mA
@load250kΩ
1mA
4.001~40.00 MΩ
0.01MΩ
+(2%+10dgt)
40.01~400.0 MΩ
0.1MΩ
+(3%+5dgt)
400.1~1000 MΩ
1MΩ
+(4%+5dgt)
500V
(0%~+10%)
0.500~4.000 MΩ
0.001MΩ
+(2%+10dgt)
1mA
@load500kΩ
1mA
4.001~40.00 MΩ
0.01MΩ
+(2%+10dgt)
40.01~400.0 MΩ
0.1MΩ
+(2%+5dgt)
400.1~1000 MΩ
1MΩ
+(4%+5dgt)
1000V
(0%~+10%)
1.000~4.000 MΩ
0.001MΩ
+(3%+10dgt)
1mA
@load1MΩ
1mA
4.001~40.00 MΩ
0.01MΩ
+(2%+10dgt)
40.01~400.0 MΩ
0.1MΩ
+(2%+5dgt)
400.1~1000 MΩ
1MΩ
+(4%+5dgt)